Derating, Notice – NORD Drivesystems TI 275271017 User Manual

Page 2

Advertising
background image

EtherCAT Bus module – SK CU4-ECT

2

TI 275271017 - 4913

Digital input - working range

Low: 0 V … 5 V, High: 15 V … 30 V

Digital input - specific data

R

i

= 10 kΩ, input capacity: 10nF, reaction time 1 ms, inputs

according to EN 61131-2 type 1

Bus specifics

EtherCAT

Max. 100 MBaud

Cable

Min. Ethernet CAT-5

Electrical isolation 500 V

eff

Max. cable length

100 m between two
modules

Bus connection

Screw terminals

Shield

Direct to PE

bus termination

performed automatically

PE connection

via PE screw connection

Status display

6 LEDs

in the terminal box

Topology

Linear bus

Process data

8 Byte per FI + 2 Byte for
IOs.
Total length 2 … 34 Byte

Performance

Update interval of process data for 1000 devices

≈ 1 ms

Update interval for process data between module and frequency inverter

≈ 5 ms

Parameter read access on the frequency inverter

≈ 12 ms

Parameter write access with storage in EEPROM

≈ 25 ms

Pos : 5 /T ec hnis che Inf or mationen/ SK xU x - Bus - Er wei ter ung en/ Allgemein - Sys temübergreif end/D erating [SK CU 4 - . ..] @ 4\ mod_1378288335408_388. doc x @ 92917 @ 5 @ 1

Derating

NOTICE

Derating

Depending on the installation location of the module (SK 180E, SK 190E or SK 2xxE), the operating mode (S1,
S3 ...) and the installation type (wall-mounting, motor -mounting) of the frequency inverter as well as the type of
motor used (IE1 / IE2 / ...) restrictions to the permissible ambient temperature must be taken into account. If the
permissible ambient temperature is exceeded, the module may heat up to an impermissible extent and switch off
with an error message (E104.0).

Maximum ambient temperature *

Operating mode

Installation type

SK 180E / SK 190E

SK 2xxE

S1

Motor

25°C

30°C

S3 ED 50 %, 10min

Motor

40°C

n. s.

S3 ED 70 %, 10min

Motor

n. s.

40°C

S1

Wall (unventilated)

37°C

42°C

S1

Wall (ventilated)

47°C

48°C

* The limits of the frequency inverter must not be exceeded (refer to the frequency inverter manual).