Module features, Installation – NORD Drivesystems TI 275281115 User Manual

Page 2

Advertising
background image

PROFINET IO Bus module – SK TU4-PNT

2 / 8

TI 275281115 - 4913

Digital input - working range

Low: 0 V … 5 V, High: 15 V … 30 V

Digital input - specific data

R

i

= 8 kΩ, input capacity: 10 nF, response time 3 ms,

inputs as per EN 61131-2 type 1

Digital output - 24 VDC power supply

≤ 400 mA (input)

Digital output - working range

Low = 0 V, High = 24 V; max. 200 mA

Bus specification

EtherNet/IP

Max. 100 MBaud

Cable

Min. Ethernet CAT-5

Electrical isolation 500 V

eff

Max. cable length

100 m between two
modules

Bus connection

2 x RJ45

Shield

Via RJ45 directly to PE

Bus termination

performed automatically

PE connection

via PE screw connection

Status display

8 LEDs

in the terminal box

Topology

Star, tree, ring, linear bus

Performance

Update interval for process data between module and frequency inverter

≤ 5 ms

Parameter read access on the frequency inverter

≈ 15 ms

Parameter write access with storage in EEPROM

≈ 25 ms

Cycle times

≥ 1 ms

Pos : 8 /T ec hnis che Inf or mationen/ SK xU x - Bus - Er wei ter ung en/ PR OFIN ET I O/M er kmal e [ PNT Allgemei n] @ 4\ mod_1385365458675_388. doc x @ 106301 @ 5 @ 1

Module features

Communication

RT (Real Time)
à Real time communication of process data

IRT (Isochronous Real Time)
à Isochronous real time communication of synchronised
process data

Addressing

Automatic address assignment via IO controller using DCP
(Discovery Configuration Protocol)

Data transfer

via Switched Ethernet

Autonegotiation

Negotiation of transfer parameters

Autocrossover

Transmission and receiver cables are automatically
crossed in the switch as necessary

Conformity classes

CC-B, and CC-C

Access for NORD diagnosis tool via

diagnosis socket on the device (if available) and possibly
via frequency inverter and
Ethernet protocols UDP or TCP/IP

Pos : 11 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ Allgemei n - Syst emübergreifend/M ontage [ SK TU4- xxx- xxx] @ 2\ mod_1353315135994_388. doc x @ 51251 @ 5 @ 1

Installation

The module must be attached to the suitable connection unit (SK TI4-TU- …) and connected using the
four M4 x 40 mm provided hexagon socket collar screws. Installation details can be found in the data
sheet for the relevant connection units.