Parameters, Further documentation and software (www.nord.com) – NORD Drivesystems TI 278910140 User Manual

Page 4

Advertising
background image

Control box – SK POT1-2

4

TI 278910140 - 3313

Parameters

For the correct function of the control box, the following frequency inverter parameters must be
modified (for details, please refer to the frequency inverter manual).

Parameter [-Array]

Meaning

Setting / Remarks

SK 180E,
SK 190E,
SK 2x0E,
SK 54xE

SK 2x5E with
SK xU4-IOE

SK 500E …
SK 535E

P400 [-01]

P400 [-03]

P400

Analog input function

"01" = Setpoint frequency

P420 [-01]

P480 [-05]

P420

Digital input (1)

"01" = Enable right

P420 [-02]

P480 [-06]

P421

Digital input (2)

"02" = Enable left

Optional (if required)

P428

P428

P428

Automatic start with
"Mains On"

"01" = On (automatic start enabled)

Pos : 8 /T ec hnis che Inf or mationen/ Bedi enboxen [SK POT 1-.. .]/ Weit erführende Dokumentationen und Soft ware [ SK PO T1-. ..] @ 3\ mod_1368009833611_388. doc x @ 64839 @ 5 @ 1

Further Documentation and Software (

www.nord.com

)

Software

Name

Software

Meaning

NORD CON

Parameterisation and diagnostic software

Document

Name

Document

Meaning

BU 0000

Description of the NORD CON software

BU 0200

SK 2xxE frequency inverter manual

BU 0040

ParameterBox manual

BU 0500

SK 500E – SK 535E frequency inverter manual

BU 0190

Frequency inverter manual SK 180E, SK 190E

BU 0505

SK 540E – SK 545E frequency inverter manual

=== Ende der List e f ür T ext mar ke I nhalt ===