Prochem Triad Air Mover User Manual

Page 22

Advertising
background image

22

86333800 TRIAD THRUSTER FAN

Maintenance

Troubleshooting

PROBLEM

CAUSE

SOLUTION

No Power, Nothing Runs

Power cord not plugged in

Plug in cord

Circuit breaker tripped on fan console

Find source of fault, correct, reset breaker

GFCI tripped on fan console

Find source of fault, correct, reset GFCI

Circuit breaker tripped in building

Reset Breaker

Loose wiring connectors

Check wiring, ensure good connection

Faulty circuit Breaker

Replace Breaker

Faulty GFCI

Replace GFCI

Fan Runs but poor air flow

Intake nozzle is blocked

Remove blockage

Exhaust nozzle is blocked

Remove blockage

Fan will not run, but GFCI
outlet has power

Loose wiring connectors

Check wiring, ensure good connection

Faulty switch

Replace switch

Faulty motor capacitor

Replace Capacitor

Faulty fan motor

Replace motor / impeller assembly

GFCI does not have power,
but fan runs

Loose wiring connectors

Check wiring, ensure good connection

Faulty GFCI

Replace GFCI

Light on switch does not
work but fan runs

Loose wiring connectors

Check wiring, ensure good connection

Faulty switch

Replace switch