10 Technical data

10.1 Specifications

General

HF52

HF53

HF55

Device type

Humidity temperature transmitter with analog output
signals

Humidity temperature
transmitter with digital
output

Circuit type

2-wire, loop powered

3-wire

Mechanical configuration types

D and W

Power supply and connections

HF52

HF53

HF55

Supply voltage (VDD)

10…28VDC
V min = 10 V + (0.02 x
Load*) *Load
resistance in ohms.

Option 1 (standard):
15…40 VDC or
12…28 VAC

Option 2: (

galvanically

isolated):
9 to 36 VDC or
7 to 24 VAC

Option 1 (standard):
5…40 VDC or
12…28 VAC

Option 2: (

galvanically

isolated):
9 to 36 VDC or
7 to 24 VAC

Option 3: PoE (not
available on models
with RS-485
interface)

Typical current consumption

2 x 20 mA

100 mA

Model with USB
interface: 100 mA

Model with Ethernet
interface: 300 mA

Electrical connections

Terminal block and M16 cable grip

or ½” conduit

adapter

Connector (USB or
Ethernet), terminal block
(power supply and RS-
485) and M16 cable grip
or ½” conduit adapter

Polarity protection

Protective diode on V+


Humidity and temperature
measurement

See document E-M-HC2 Probes > Specifications


Calculated parameters

HF52

HF53

HF55

Psychrometric calculations

Dew point (Dp) above and below freezing
Frost point (Fp) below freezing and dew point above freezing
Wet bulb temperature (Tw)
Enthalpy (H)
Vapor concentration (Dv)
Specific humidity (Q)
Mixing ratio by weight (R)
Vapor concentration at saturation (Dvs)
Vapor partial pressure (E)
Vapor saturation pressure (Ew)