INSTALLATION

SECTION 3-4

Elcectrical Wiring

ELECTRICAL WIRING


To wire the granulator, run power (of the proper voltage) from the plant source through a lockable,

fusible disconnect to the machine electrical control panel.


Wiring from the pneumatic cylinder console to the safety switches, zero speed sensor and hydraulic
pump/valves or cutting chamber/screen cradle jackscrew is done at the factory.

From the main electrical panel, make the necessary wiring connections to the main drive motor and any
auxiliary motors or control connections.

Refer to the wiring diagram appended to this manual for wiring connections for typical machine

applications. Check the wiring diagram supplied for any wiring that is specific to your application. This

diagram is part of the documentation shipped with the machine.

After power is connected, do not make any adjustments to the machine without performing the

following operations.

TURN POWER OFF and LOCK IT OUT per OSHA 1910.147 OR ANSI Z244.1-1982 (Lockout/Tag-
out of Energy Sources).

If you cannot lock out the power, have an electrician remove the fuses.

Tag the machine as OUT OF SERVICE.

Make sure the rotor has come to a complete stop.

The pneumatic cylinder, which opens the rear of the machine, should not operate until the rotor is

completely stopped. If you discover that the pneumatic cylinder DOES operate while the rotor is still

turning, immediately shut down the machine and call for maintenance to adjust it.

Wear gloves to protect against injury from the rotor or bed knives.