SETTINGS AND ADJUSTMENTS
SECTION 4-2
Adjusting or Replacing Bed Knives
(Continued from previous page)
The hydraulic cylinders or jackscrews, which open the machine, should not operate until the rotor is
completely stopped. If you discover that the hydraulic cylinders or jackscrews DO operate while the rotor
is still turning, immediately shut down the machine and call for maintenance to adjust it.
Wear gloves to protect against injury from the rotor or bed knives.
OPEN THE FRONT CUTTING CHAMBER
INTERLOCK
Disengage the interlock actuator screws
Back the screws out as far as they will go. When
unscrewed, the interlock will still be captive on the
door to prevent loss.
When disengaged, the interlock opens the electrical
control circuit to the motor and prevents the machine
from running.
Remove the granulate deflector and set aside
RELEASE THE SCREEN FASTENERS
Loosen the mounting cradles and remove one at a
time.
Pivot the cradles down until they rest on the floor.
SEE SECTION 6-10 PAGE 87 FOR COMPLETE CUTTING CHAMBER OPENING
INSTRUCTIONS.