Maintenance – Sterlco ST500 Series Central Granulator User Manual
Page 68

68
MAINTENANCE
SECTION 6-3
Periodic Maintenance
INFEED FLAP CONDITION
Daily, check the overall condition of the (3) infeed flaps, pictured in Section 2, Left Quarter View.
Check for wear, or tears in the flap, or if pieces are missing. Replace them if you see damage. Check
the rods that support the flaps: they should be in good condition and in proper location. Any flap and
or its mounting hardware that is deteriorated should be replaced to assure proper machine performance
and operation.
PNEUMATIC CYLINDER INSPECTION -PIVOT PINS AND LOCKNUTS
Weekly, check the overall condition of the pneumatic cylinders, shown in Section 2, Left/Rear Quarter
View and on page 56. If you find problems with the mounting hardware, do not operate the units. Call
for maintenance to correct the problems.
Visually check the cylinder in its extended position.
Check the condition and position of the pivot pins at top and bottom ends of the cylinders