Front chamber access, Maintenance – Sterlco ST500 Series Central Granulator User Manual

Page 73

Advertising
background image

73

MAINTENANCE

SECTION 6-8

Cutting Chamber Access

FRONT CHAMBER ACCESS

TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI Z244.1-1982

(Lockout/Tag out of Energy Sources).

If it is not possible to lock out the power, have an electrician remove the fuses.

Make sure the rotor has come to a complete stop.

Wear gloves to protect against injury from the rotor or bed knives.

OPEN THE CUTTING CHAMBER SAFETY
INTERLOCK

Disengage the interlock actuator screws
Back the screws out as far as they will go. When

unscrewed, the interlock will still be captive on the
door to prevent loss.

When disengaged, the interlock opens the electrical

control circuit to the motor and prevents the
machine from running.

Remove the granulate deflector and set aside

WARNING CUTTING CHAMBER OPENING

RELEASE THE SCREEN FASTENERS

Loosen the mounting cradles and remove one at a

time.

Pivot the cradles down until they rest on the floor

Advertising