11 event output parameters – TOHO ELECTRONICS TTM-00BT User Manual

Page 11

Advertising
background image

11

Event output parameters

a) Identifier

b) Name

c) R/W

d) Description and set range

e) Remark

Initial value (communication
numerical data)
TC, thermocouple;
Pt, resistance bulb

E * F

*: 1 to 8













00000

Temperature alarm
output*functional setting

R/W

R/W of the temperature alarm output*functional
setting

000 * *

PV temperature alarm functions

Type

0 None

1 Deviation top/bottom limit alarm

Additional functions

2 Deviation top limit alarm

Type

3 Deviation bottom limit alarm

0 None

4 Deviation range alarm

1 Hold

5 Absolute value top/bottom limit

alarm

2 Standby sequence

6 Absolute value top limit alarm

3 Hold + standby

sequence

7 Absolute value bottom limit

alarm

8 Absolute value range alarm

*1

E * H

*: 1 to 8

00000

Set a temperature alarm
output*top limit

R/W

r/w

R/W of the temperature alarm output*top limit setting

Set range: -199 to1500

°

C/-199.9 to 1500.0

°

C

*1

E * L

*: 1 to 8

00000

Set a temperature alarm
output*bottom limit

R/W

r/w

R/W of the temperature alarm output*bottom limit
setting
Set range: -199 to1500

°

C/-199.9 to 1500.0

°

C

*1

E * C

*: 1 to 8

00000

Set a temperature alarm
output*sensitivity

R/W

R/W of the temperature alarm output*sensitivity
setting
Set range: -199 to1500

°

C/-199.9 to 1500.0

°

C

*1

CTF




00000

CT function

R/W

R/W of the presence or lack of an alarm about heater
wire break and SSR breakdown
00000: None
00001: Heater wire break alarm function
00002: SSR breakdown alarm function
00003: Heater wire break + SSR breakdown alarm
function

Heater wire break:
LED12
SSR breakdown:
LED13

C * I

*: 1 to 8

00000

CT allocation channel

R/W

R/W of the status about the channel to which CT*(1 to
8) should be allocated
00000: None (not allocated)
00001 to 00008: (CH)

Channel not specified

ALB

00000

Error alarm function

R/W

R/W of the presence or lack of memory errors, A/D
errors, and sensor error alarms
00000: None
00001: Present

Error alarm: LED14

CT*

*: 1 to 8

00000

Set an output current error

R/W

R/W of the current of the heater current detector
Set range: 0.0 to 50.0A AC

Channel not specified