Monitor window parameters

a) Identifier

b) Name

c) R/W

d) Description and set range

e) Remark


PV1

Measurement

R

Used as a measurement monitor
When over-scale: HHHHH (the same is true when the
sensor has a wire break)
When under-scale: LLLLL

CM*

*: 1 to 8

CT measurement

R

R of the measured current of the heater current
detector
When over-scale: HHHHH
When reading is impossible: -----

When reading is
impossible: The CT
value cannot be read
unless the output of no
less than 190mS is
turned on.

DIM

DI monitor

R

R of the voltage input monitoring
00000: State where voltage input is not applied
00001: State where voltage input is applied

OM1

Monitor the control output

R

R of the control output monitoring
000①②

① Output 1 state… 1:ON/0:OFF
② Output 2 state… 1:ON/0:OFF

*2

EM1

Monitor the temperature
alarm outputs 1 to 4

R

R of the temperature alarm output monitoring
0①②③④
①: temperature alarm output 4

②: temperature alarm output 3
③: temperature alarm output 2

④: temperature alarm output 1

*3

EM2

Monitor the temperature
alarm outputs 5 to 8

R

R of the temperature alarm output monitoring
0①②③④

①: temperature alarm output 8

②: temperature alarm output 7
③: temperature alarm output 6

④: temperature alarm output 5

*3

ALM

Monitor the alarm output

R

R of the alarm monitoring
00①②③

① Alarm output of heater wire break (1:ON/0:OFF)
② Alarm output of SSR breakdown (1:ON/0:OFF)

③ Error alarm output (1:ON/0:OFF)