UEi Test Instruments KM900PLUS User Manual

Page 19

Advertising
background image

KANE900 Plus Operators Manual

Page 18

Once an alarm has been exceeded the display will flash every two minutes warning
the user of an alarm state and display the gas concentration. A similar display will be
shown during a RECHARGE BATTERY and PUMP OFF alarms.

-- -- -- -- -- -- -- -- -- -- -- -- -- --

CO ALARM

1010 ppm

-- -- -- -- -- -- -- -- -- -- -- -- -- --

NO REF:

Displayed on the Nitric Oxide unit only. Allows
the percentage P in the following calculation to be
set. The default value set is 5%. Note the
percentage allows for NO

2

in a typical boiler.


NO

x

= NO + P% NO

OFF
1-9 %


CALENDAR: Allows the user to change the date and time. (24

hour clock).
The following screen will be shown once the
parameter is entered:


TIME :
FORMAT :
DATE :

hh
13
dd
03

: mm : ss
:
53 : 26
:
mm : yy
:
01 : 96

FORMAT :

Changes the date format for display and printing.

dd : mm : yy
yy : mm : dd
mm : dd : yy

To change the time position the cursor on Time and press

. The cursor will

now be to the left of the 13 as shown below:


TIME :
FORMAT :
DATE :

hh
13
dd
03

: mm : ss
:
53 : 26
:
mm : yy
:
01 : 96

Using

and

scroll through the setting options i.e. 0-23.

Once the correct hour is set press

to move to the next parameter, the cursor

will move to the left of minutes (53). Move to each parameter until the correct time is
set.

Pressing

after setting the seconds will return the cursor to the left of the

screen.


Format and Date are set in a similar manner.