4.3 Main

Displays


The main display can be changed to show either 4 or 8 parameters at one time. Two
options are available when 4 parameters are selected.

4 Page Mode displays 4 lines of data in set format, each page is predefined.
Line scroll mode allows you to customise the display to show the data you

require.

8 Page Mode displays 8 parameters on 4 lines in set format, the bottom two can be

changed.


Changing between the different modes is detailed in Display Menu Section 5.2.4.

4.3.1 4 Page Mode

Use the

and

keys to change the information that is displayed on the

screen. The following pages are available.

NATURAL GAS
DATE 07-08-96
TIME 12:31:35
BATTERY % 54

NETT C 0.0
O2 % 20.9
CO ppm 0000
EFF (G) % 0.0

CO2 % 0.0
FLUE C 0.0
INLT NOT FITTED
AMBIENT C 21.5

CO/CO2 R 0.0001
P INDEX % 0.01
XAIR % 0.0
Prs mbar 0.00

This screen only displayed on an
analyser fitted with an NO sensor

NO ppm 0000
NOx ppm 0000
NOx calc% 5
O2 ref % 3.0

TIP - In 4 page mode only

turns the backlight ON and OFF.