Specification – UEi Test Instruments AQM4 User Manual

Page 24

Advertising
background image

23

Measuring Range

CO²

0 ~ 9999ppm

CO

0 ~ 1000ppm

Temperature

-20 ~ 60˚C

-5 ~ 140˚F

Relative Humidity

0.1% ~ 99.9%

Dew Point Temp.

-20.0 ~ 59.9˚C

Wet Bulb Temp

-5.0 ~ 59.9˚C

Resolution

1ppm, 0.1˚C/˚F, 0.1%RH

Accuracy

CO²

±30ppm ± 5% of

reading (0 ~ 5000ppm)

CO

±10ppm for less than

100ppm

±10% of reading for

101~500ppm

±20% of reading for 501ppm

and above

Temperature

±0.6˚C/+0/9˚F

Relative Humidity

±3% (at 25˚C, 10~90%)

±5% (at 25˚C, other range)

Response Time

CO²

<30 seconds

(90% step change)

CO

<60 seconds

(90% step change)

Tair

<2 mins

(90% step change)

Relative Humidity

<10 mins

(90% step change)

LCD/Meter Size (mm)

26(H) x 44 (L),

205(L) x 70 (W) x 56(H)

Operating Condition

-20 to 50˚C (CO² Sensor)

0 to 500˚C (CO Sensor)

-20 to 60˚C

Storage Condition

-20 ~ 60˚C, 10 ~ 90% RH

Power Supply

AA x 4pcs or 9V Adaptor

Battery Life

>24 hours

(Alkaline Battery)

Weight

200g

SPECIFICATION