2 1d barcodes – Brother TD-2120N User Manual

Page 29

Advertising
background image

P-touch Template 2.0 Command Reference

- 23 -

4. P-touch Template 2.0 Limitations

4.2.2 1D barcodes

A barcode wider than 22.5 cm will not be printed.

A 1D barcode taller than 1164 dots is converted to 1164dots.

The number of characters that can be entered for each protocol is shown below.

CODE39

1 to 50 characters (not including “*” on both sides)
When feeding data, the asterisks (*) at the beginning and end of the data are
skipped.

ITF

I-2/5

1 to 64 characters
The bearer bar setting specified in P-touch Editor is invalid.

EAN-8 7

characters

EAN-13 12

characters

UPC-A 11

characters

UPC-E 6

characters

CODABAR

3 to 64 characters (with “A”, “B”, “C” or “D” at the beginning and end)

CODE128

1 to 64 characters

GS1-128

(UCC/EAN-128)

1 to 64 characters

RSS-14

3 to 15 characters (begins with “01”)

RSS Limited

3 to 15 characters (begins with “01”; third digit is “0” or “1”)

RSS Expanded

1 to 64 numbers or 1 to 40 letters*

POSTNET

5, 9 or 11 characters

* ISO646 characters can be printed.

<<numbers, letters, spaces, !, ”, %, &, ’, (, ), *, +, ,, -, ., /, :, ;, <, =, >, ? and _>>

When trying to transfer data exceeding the ranges described above, an error will occur while

transferring. If the data that is fed does not meet the minimum limit, the barcode is not printed. If the

data exceeds the maximum limit, only the data to the maximum limit is applied. However, if the data

exceeds 64 characters, the barcode is not printed.