New eu portable manual_en_fr_it_es_pt_14 – Electrolux EXP09HN1WI User Manual
Page 14
14 www.electrolux.com
SLEEP OPERATION:
In this mode the selected temperature 
will increase by 1 °C 30 minutes after 
the mode is selected. The temperature 
will then increase by another 1 °C after 
an additional 30 minutes. This new 
temperature will be maintained for 
7 hours before it returns to the originally 
selected temperature. This ends the 
"Sleep" mode and the unit will continue 
to operate as originally programmed. 
The "Sleep" mode program can be 
cancelled at any time during operation 
by again pressing the "Sleep" button.
Note: This feature is unavailabe under 
FAN or DRY modes.
SWING OPERATION:
When you turn on the unit, the louver 
will swing and stop at a certain angle. 
You can press the SWING button to let 
the louver swing automatically. Press 
the SWING button again while you want 
the louver stop at desired angle.
FAULT CODE:
If the display reads "E1", the room 
temperature sensor has failed. Call for 
service.
temp/timer setting
If the display reads "E2", the evaporator 
temperature sensor has failed. Call for 
service. 
temp/timer setting
If the display reads "E3", the condenser 
temperature sensor has failed. Call for 
Service.
temp/timer setting
If the display reads "E4", the display panel 
communication has failed. Call for sen/ice. 
temp/timer setting
If the display reads "P1" , bottom tray 
is full. Carefully move the unit to a drain 
location, remove the bottom drain plug 
and let the water drain away. Restart the 
machine until the "P1" symbol disappears. 
If error repeats, call for service.
temp/timer setting
DRAINAGE:
1. During the dehumidifying mode, 
you will need a garden hose (sold 
separately) to drain the condensate 
from the unit. Remove the rubber 
stopper from the hose connector, 
then screw on a garden hose to the 
connector as shown on fig 25.
The hose may then:
A. Discharge into a drain that is lower 
than the unit.
B. Be connected to a condensate
pump (sold separately).
Remove the 
supplied rubber 
stopper
Garden hose
&IGÒ
Garden hose
Remove the 
supplied rubber 
stopper
2. During the Heating mode, you will
need to connect a drain hose to the 
rear of unit as Fig.26
&IGÒ
Continuous
drain hose
Continuous 
drain hose