Remote or Inline Blower (see Figures 10

and 11 for further detail):
Y A. Remove junction box cover and con-

nect conduit with 5 wires from remote

blower. Hook up wires per Wiring.Fig. 10.

Replace junction box cover.

Y B. Attach Duct Transition Box at moun-

ting holes with sheetmetal screws.

Y C. Feed remote blower pigtail through

strain relief.

Y D. Attach strain relief to downdraft near

junction box.

Y E. Connect pigtail to downdraft at 6 pin

connector.

Y F. Run pigtail wires to junction box.
Y G. Inside junction box, connect conduit

with five wires from remote or inline blo-

wer. Use a conduit connector to secure.

Fig. 10 – Remote Blower

Integral Blower VTN600CV2C (see Figures

10 and 12 for further detail):

Note: Blower and duct transition box may

be installed with duct outlet left, down or

right. Install blower or duct transition in

such a way that access panels can be

removed for service.
Y H. Place the cooktop in countertop ope-

ning with the rear edge of cooktop over-

lapping the front edge of the vent. Make

sure rear edge of cooktop does not bind

against front of snorkel.

Follow the manufacturer’s installation In-

structions for installing gasket strips,

protective heat tape (if required), secu-

ring the cooktop to the countertop and

making the cooktop electrical and/or gas

connections.

Note: Check boxes as tasks are completed.

Strain Relief

Remote Blower

Pigtail

6 Pin Connector

Junction Box

Duct Transition Box

Conduit To Re-

mote Blower

10