Step 7: Mount Integral Blower or
Outlet Duct Transition for Remote or
Inline Blower

Integral Blower (see Figures 9 and 11 for

further detail):
Y A. Attach blower in front of round ex-

haust outlet with 4-6 (depending on con-

figuration) #8 sheetmetal screws.

Y B. Feed cord from blower through strain

relief.

Y C. Secure strain relief with screws.
Y D. Attach strain relief to downdraft near

junction box.

Y E. Connect cord to downdraft at 6 pin

connector.

Y F. Connect blower to ductwork.

4-  4

'- &44

 $

 4/ 

Fig. 9 – Internal Blower

Step 7: Mount Integral Blower or
Outlet Duct Transition for Remote
Blower

Integral Blower VTN600CV2C (see Figures

10 and 12 for further detail):

Y G. Place the cooktop in countertop ope-

ning with the rear edge of cooktop over-

lapping the front edge of the vent. Make

sure rear edge of cooktop does not bind

against front of snorkel. Follow the ma-

nufacturer’s installation Instructions for

installing gasket strips, protective heat

tape (if required), securing the cooktop

to the countertop and making the cook-

top electrical and/or gas connections.

Note: Check boxes as tasks are completed.

Internal Blower

Strain Relief

6 Pin

Connector

9

Advertising
This manual is related to the following products: