WARNING

To reduced the risk of fire, electric shock,

or injury to persons, observe the follo-

wing:
A. Installation work and electrical wiring

must be done by authorized person(s)

in accordance with all applicable

codes and standards, including fire-

related construction.

B. Sufficient air is needed for proper

combustion and exhausting of gases

through the flue (chimney) of fuel bur-

ning equipment to prevent backdraf-

ting. Follow the heating equipment

manufacturer’s guideline and safety

standards such as those published by

the National Fired Protection Associa-

tion (NFPA), and the American Society

for Heating, Refrigeration and Air

Conditioning Engineers (ASHRAE),

and the local code authorities.

C. When cutting or drilling into wall or

ceiling, do not damage electrical

wiring and other hidden utilities.

D. Ducted fans must always be vented

to the outdoors.

E. Always unplug or disconnect the

appliance from the power supply

before servicing.

F. This unit is designed for indoor use

only. Use this unit only in the manner

intended by the manufacturer.

G. Make certain the cooktop is appro-

priate for use with a downdraft vent.

H. Not intended for use with professio-

nal-style cooktops.

WARNING

For general ventilating use only. Do not

use to exhaust hazardous or explosive

materials and vapors.

To reduce risk of fire and to properly ex-

haust air, be sure to duct air outside. Do

not vent exhaust air into spaces within

walls, ceilings, attics, crawl spaces or

garages.

To reduced the risk of fire, use only metal

duct work.

To reduce the risk of fire, electric shock

and injury to persons, Downdraft must

be used with Internal, Remote or Inline

Blower.

To reduce the risk of fire or electric

shock, do not use the fan with any solid-

state speed control device.

This appliance has been found to be in

compliance with UL 507 Standard for

Electric Fans and CAN/CSA-22.2 No.

113 Canadian Standard for Fans and

Ventilators. It is the responsibility of the

owner and the installer to determine if

additional requirements or standard

apply in specific installation.

SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

READ AND SAVE THESE INSTRUCTIONS

Parts Needed (standard)

Tape Measure

Phillips Head Screwdriver

Aluminum Duct Tape

Ductwork (configuration varies

depending on location; See pages 7-12

for further information)

Additional Sheetmetal screws (as neces-

sary for ductwork installation)

Saw (or equivalent for cutting counter-

top)

#8 x 1 1/4” Wood Screws (4)

Plumb Bob

Wire to reach Remote or Inline Blower

Parts Needed (special)

Special Blower

Transition Box (for use only with Inline

and Remote Blowers)

Recirculation Module (used only for

recirculation applications)

Note: Downdrafts work with these

blowers: 600 CFM Integrated, Remote or

Inline Blowers 1000 CFM Remote or Inline

Blowers

Parts Supplied

Downdraft assembly (1)

#8 Sheetmetal Screws (8)

Blower Cord Strain Relief (1)

Hardware for brackets on vent (2)

Remote Blower Pigtail