INTRODUCTION
GENERAL DESCRIPTION

The complete downdraft system consists of

the downdraft, a blower and a transition

box if using an Inline or Remote Blower. A

recirculation module is also available when

ducting to the outside is not preferred or

not possible. (See Fig. 1).

The blower can be either integral (mounted

on the vent intake in the cabinet under the

cooktop), an inline (mounted between the

kitchen and exterior wall anywhere within

the duct line), or a remote (mounted on the

roof or outside wall). When a remote or inli-

ne blower is used, a duct transition is

mounted on the ventilator intake in place of

the integral blower to connect the intake to

the duct work. The duct transition must be

purchased separately.
The integral blower or duct transition can

be mounted in different positions on the

intake to route ductwork to avoid cabinet,

building framing, utilities, etc.
The downdraft system is available in 30-

inch or 36- inch. Intended for non-profes-

sional style cooktops only.
A Recirculation Kit can be purchased sepa-

rately and used in conjunction with the Inte-

gral Blower if ducting to the outside is not a

viable option.

Step 1: Plan the installation

Carefully follow the planning procedures

listed below (See Figure 2). Sketches are

NOT intended to be a replacement for care-

ful planning.
A. Determine whether a remote, inline, or

integral blower will be used. Remote

and inline blower installation requires

4 wires plus a ground wire to run from

the downdraft to the blower.

B. Make sure that adequate cabinet and

counter space has been provided and

that the intake and blower will be acces-

sible if service is required.

C. Consider that cross drafts created by

adjacent open windows, doors, air con-

ditioning, old heating vents, recessed

ceiling lights, and traffic patterns may

affect performance.

D. For gas cooktop installations make sure

that a minimum 10 square inch opening

is provided in the toe-kick or other cabi-

net area. Inadequate ventilation of the

cabinet below the cooktop may result in

flame outage when operating the vent

system.

E. Provide for air supply or ”make-up

air” to the room where unit will be

installed. If ”make-up air” is not provi-

ded, then problems, such as fireplace

chimney downdrafts, could result.

Fig. 1

Downdraft - Unit

Strain Relief

Blower /
Duct Transition Box
(Not Included)

4