Electrical connections warning, Warning – LG LSCI307ST User Manual

Page 23

Advertising
background image

23

ENGLISH

I N S TA L L AT I O N I N S T RU C T I O N S

IMPORTANT SAFETY INSTRUCTIONS

• Be sure your cooktop is installed and grounded

properly by a qualified installer or service technician.

• This cooktop must be electrically grounded in

accordance with local codes or, in their absence,

with the National Electrical Code ANSI/NFPA No. 70,

latest edition in the United States.

PROVIDING THE ELECTRICAL
CONNECTION

Install the junction box under the cabinet and run

120/240 or 120/208 volt, AC wire from the main

circuit panel.
NOTE: DO NOT connect the wire to the circuit

panel at this time.

ELECTRICAL REQUIREMENTS

Observe all governing codes and local

ordinances.

A 3-wire or 4-wire single-phase 120/240 or

120/208 volt, 60 Hz AC-only electrical supply is

required on a separate circuit fused on both sides

of the line (time-delay fuse or circuit breaker is

recommended). DO NOT fuse neutral. The fuse

size must not exceed the circuit rating of the

appliance specified on the nameplate.
This unit can consume up to 7,400W at 240 VAC.

A 40 Amp circuit breaker with wire gauge #8 AWG

must be used.

NOTE: Wire sizes and connections must conform

with the fuse size and rating of the appliance in

accordance with the National Electrical Code

ANSI/NFPA No. 70, latest edition, and local codes

and ordinances.

The appliance should be connected to the fused

disconnect (or circuit breaker) box through flexible

armored or nonmetallic sheathed cable. The

flexible armored cable extending from this

appliance should be connected directly to the

grounded junction box. The junction box should be

located as shown on page 22 with as much slack

as possible remaining in the cable between the

box and the appliance, so it can be moved if

servicing is ever necessary.
A suitable strain relief must be provided to attach

the flexible armored cable to the junction box.

ELECTRICAL CONNECTIONS

WARNING

The electrical power to the cooktop must be shut

off while line connections are being made. Failure

to do so could result in serious injury or death.

WARNING

An extension cord must not be used with this

appliance. Such use may result in a fire, electrical

shock, or other personal injury.

1

2

3

4

Advertising