Installing more than the required number of fans in a single-processor configuration is not a

supported configuration.
For a dual-processor configuration, six fans are required for redundancy. A fan failure or missing fan

causes a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the

server.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature

change requires a fan speed increase to cool the server. The server shuts down during the following

temperature-related scenarios:

●

At POST and in the OS, HP iLO performs an orderly shutdown if a cautionary temperature level

is detected. If the server hardware detects a critical temperature level before an orderly

shutdown occurs, the server performs an immediate shutdown.

●

When the Thermal Shutdown feature is disabled in RBSU, HP iLO does not perform an orderly

shutdown when a cautionary temperature level is detected. Disabling this feature does not

disable the server hardware from performing an immediate shutdown when a critical

temperature level is detected.

CAUTION:

A thermal event can damage server components when the Thermal Shutdown

feature is disabled in RBSU.

Hot-plug fans 17