HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 103

Command line 103
Item
Description
Parameters
PortID (required) The ID of the port to remove from a network. The port ID must be in the format
<EnclosureID>:<InterconnectBayNumber>:<PortNumber>.
If EnclosureID is not specified, it defaults to the local enclosure.
Network
(optional)
The name of the network from which the port is removed
UplinkSet
(optional)
The name of the shared uplink set from which the port is removed
Examples
->remove uplinkport enc0:1:2 Network=MyNetwork
Removes a specific uplink port (Bay 1, Port 2) from a network named MyNetwork
->remove uplinkport * Network=BlueNetwork
Removes all uplink ports from a network named BlueNetwork
->remove uplinkport enc0:2:3 UplinkSet=SharedUplinkSet1
Removes a specific uplink port (Bay 2, Port 3) from a shared uplink set
Item
Description
set uplinkport
Modify an uplink port that exists as a member of a network or shared uplink port set.
Syntax
set uplinkport <PortID> [Network=<NetworkName>|
UplinkSet=<UplinkSetName>][Speed=<Auto|10Mb|100Mb|1Gb|
10Gb|Disabled>] [Role=<Primary|Secondary>]
Parameter
PortID (required) The ID of the port to modify. The specified port must already be added to a network or
shared uplink set. The port ID is in the format
<EnclosureID>:<BayNumber>:<PortNumber>.
Properties
Network
(required)
The name of the network to which the port belongs if the shared uplink set name is not
specified
UplinkSet
(required)
The name of the shared uplink set to which the port belongs if the network name is not
specified
Speed (optional) Specifies the port speed for the port. Valid values include "Auto", "10Mb", "100Mb",
"1Gb", "10Gb", and "Disabled".
If no connector is present on the uplink port, only "Auto" and "Disabled" can be
configured as the speed. Speed restrictions apply.
Role (optional)
The role played by the port if the connection mode of the network or shared uplink set
is selected as "Failover". Valid values are "Primary" and "Secondary". The default
value is "Primary".
Examples
->set uplinkport enc0:1:2 Network=MyNetwork Speed=1Gb
Changes the port speed of a network port
->set uplinkport enc0:2:1 Network=MyNetwork Speed=Disabled
Disables a specific port that belongs to a network
->set uplinkport enc0:2:4 UplinkSet=MyUplinkSet Speed=Disabled
Disables a specific port that belongs to a shared uplink set
->set uplinkport enc0:2:4 Network=MyNetwork Role=Secondary
Modifies the role of the network uplink port with the connection mode on the network or
the shared uplink set as "Failover" to take the Secondary port role
Item
Description
show uplinkport
Display all Ethernet module uplink ports known to the domain. If the port is a member
of a network or a shared uplink set, it appears. If the port is unlinked and no
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem