HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 103

Advertising
background image

Command line 103

Item

Description

Parameters

PortID (required) The ID of the port to remove from a network. The port ID must be in the format

<EnclosureID>:<InterconnectBayNumber>:<PortNumber>.

If EnclosureID is not specified, it defaults to the local enclosure.

Network

(optional)

The name of the network from which the port is removed

UplinkSet

(optional)

The name of the shared uplink set from which the port is removed

Examples

->remove uplinkport enc0:1:2 Network=MyNetwork

Removes a specific uplink port (Bay 1, Port 2) from a network named MyNetwork

->remove uplinkport * Network=BlueNetwork

Removes all uplink ports from a network named BlueNetwork

->remove uplinkport enc0:2:3 UplinkSet=SharedUplinkSet1

Removes a specific uplink port (Bay 2, Port 3) from a shared uplink set

Item

Description

set uplinkport

Modify an uplink port that exists as a member of a network or shared uplink port set.

Syntax

set uplinkport <PortID> [Network=<NetworkName>|

UplinkSet=<UplinkSetName>][Speed=<Auto|10Mb|100Mb|1Gb|

10Gb|Disabled>] [Role=<Primary|Secondary>]

Parameter

PortID (required) The ID of the port to modify. The specified port must already be added to a network or

shared uplink set. The port ID is in the format
<EnclosureID>:<BayNumber>:<PortNumber>.

Properties

Network

(required)

The name of the network to which the port belongs if the shared uplink set name is not

specified

UplinkSet

(required)

The name of the shared uplink set to which the port belongs if the network name is not

specified

Speed (optional) Specifies the port speed for the port. Valid values include "Auto", "10Mb", "100Mb",

"1Gb", "10Gb", and "Disabled".

If no connector is present on the uplink port, only "Auto" and "Disabled" can be
configured as the speed. Speed restrictions apply.

Role (optional)

The role played by the port if the connection mode of the network or shared uplink set

is selected as "Failover". Valid values are "Primary" and "Secondary". The default

value is "Primary".

Examples

->set uplinkport enc0:1:2 Network=MyNetwork Speed=1Gb

Changes the port speed of a network port

->set uplinkport enc0:2:1 Network=MyNetwork Speed=Disabled

Disables a specific port that belongs to a network

->set uplinkport enc0:2:4 UplinkSet=MyUplinkSet Speed=Disabled

Disables a specific port that belongs to a shared uplink set

->set uplinkport enc0:2:4 Network=MyNetwork Role=Secondary

Modifies the role of the network uplink port with the connection mode on the network or

the shared uplink set as "Failover" to take the Secondary port role

Item

Description

show uplinkport

Display all Ethernet module uplink ports known to the domain. If the port is a member

of a network or a shared uplink set, it appears. If the port is unlinked and no

Advertising