HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 38

Advertising
background image

Command line 38

Item

Description

Adds a new FC SAN connection and uses the next available fabric

->add fc-connection MyNewProfile

AddressType=Factory-Default

Adds a new FC SAN connection and uses factory-default addresses

->add fc-connection MyNewProfile AddressType=User-Defined

PortWWN=50:06:0B:00:00:C2:62:00

NodeWWN=50:06:0B:00:00:c2:62:01

Adds a new FC SAN connection and provides user-defined WWN addresses

Item

Description

remove fc-connection

Remove the last FC connection from an existing server profile.

Syntax

remove fc-connection <ProfileName>

Parameter

ProfileName (required) The name of an existing profile from which the last FC connection is being

removed

Example

->remove fc-connection MyProfile

Removes an FC connection from a profile

Item

Description

set fc-connection

Modify an existing FC SAN connection.

Syntax

set fc-connection <ProfileName> <Port>

[Fabric=<FabricName>]

[Speed=<Auto|1Gb|2Gb|4Gb|8Gb|Disabled>]

[BootPriority=<priority>] [BootPort=<portName>]

[BootLun=<LUN>]

Parameters

ProfileName (required) The name of the server profile that contains the connection being modified
Port (required)

The port number of the connection being modified

Properties

Fabric (optional)

The name of the FC SAN fabric to associate with the connection. The fabric

being specified should be associated with the same bay as the FC connection.

A blank string makes the FC connection unassigned.

Speed (optional)

The port speed of the FC SAN connection. Valid values include "Auto", "8Gb",

"4Gb", "2Gb", "1Gb", and "Disabled".

Speed restrictions:

For the HP 4Gb VC-FC Module and HP Virtual Connect 4Gb FC Module,
supported speed values include "Auto","1Gb","2Gb", "4Gb", and

"Disabled". If the value is set to 8Gb, the speed is auto-negotiated by Virtual

Connect.

BootPriority

(optional)

Controls whether the FC HBA port is enabled for SAN boot and affects the BIOS

boot order. Valid values include "BIOS", "Primary", "Secondary", and

"Disabled".

BootPort

(Required if the Boot Priority is

either Primary or

Secondary optional)

The target WWPN of the controller interface on the Fibre Channel storage
target. The port name is a 64-bit identifier in the format

NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number.

BootLun

(Required if the Boot Priority is

The LUN of the volume used for SAN boot. Valid values include an integer from

0 to 255 or 16 hex digits (HP-UX only).

Advertising