Adding uplink ports to a shared uplink set, Creating a network that uses a shared uplink set, Server vlan tagging support – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 145: Fibre channel setup, Configuring wwn address ranges

Advertising
background image

Configuring the Virtual Connect domain using the CLI 145

Details for a single shared uplink set
>show uplinkset MyUplinkSetName

Adding uplink ports to a shared uplink set

To add uplink ports to a shared uplink set, use the add uplinkport command:

>add uplinkport enc0:1:2 uplinkset=MyUplinkSetName

Creating a network that uses a shared uplink set

To create a network that uses a shared uplink set, use the add network command:

>add network MyNewNetworkName uplinkset=MyUplinkSetName vlanid=156

Creating multiple networks that use a shared uplink set

To create multiple networks that use a shared uplink set, use the add network-range command:

>add network-range UplinkSet=SUS1 VLANIds=

Server VLAN Tagging Support

Each server port can be connected to multiple virtual networks, each using a unique server VLAN ID for virtual
network mapping.
The translation of Server VLAN tags to internal network VLAN and again to external data center VLAN tags,

and the reverse, on incoming and outgoing frames can result in a configuration where the server VLANs

might not match the external VLANs used on uplinks. To avoid this scenario, the server connections can be
forced to use the same VLAN mappings as the shared uplink sets. Setting the value to "true" restricts the server

network connections to be selected from a single shared uplink, and the VLAN ID cannot be modified:

>set enet-vlan SharedServerVLanID=true

Setting the value to "false" enables you to select any VC Ethernet network for the server Ethernet connections,

and VLAN ID mappings can be modified to ensure uniqueness:

>set enet-vlan SharedServerVLanID=false

When using mapped VLAN tags, the overall link speed can be controlled as follows:

>set enet-vlan PrefSpeedType=Custom PrefSpeed=500 MaxSpeedType=Custom

MaxSpeed=2500

Fibre Channel setup

To configure external Fibre Channel connectivity for the HP BladeSystem c-Class enclosure:

1.

Identify WWNs to be used on the server blades deployed within this Virtual Connect domain.

2.

Create FC SAN fabrics ("

Creating FC fabrics

" on page

146

).

Configuring WWN address ranges

Each server blade FC HBA mezzanine card ships with factory default port and node WWNs for each FC
HBA port. Each WWN is a 64-bit number that uniquely identifies the FC HBA port/node to other devices on

the network. While the hardware ships with default WWNs, Virtual Connect has the ability to assign WWNs

that override the factory default WWNs while the server remains in that Virtual Connect enclosure. When

configured to assign WWNs, Virtual Connect securely manages the WWNs by accessing the physical FC
HBA through the enclosure Onboard Administrator and the iLO interfaces on the individual server blades.