Creating server profiles – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 149

Advertising
background image

Configuring the Virtual Connect domain using the CLI 149

iSCSI connections are not added to server profiles by default. You must add one or more iSCSI

connections. The GUI enables the creation of iSCSI connections only if at least one Flex-10 or FlexFabric

module exists in the domain. The CLI can be used to pre-provision this feature. iSCSI and FCoE
connections cannot share the same physical Flex-10 port since they use the same physical function.

Some server profile SAN boot settings (controller boot order) are applied by Virtual Connect only after
the server blade has been booted at least once with the final mezzanine card configuration.

If PXE, controller boot order, or SAN boot settings are made outside of Virtual Connect using RBSU or
other configuration tools, Virtual Connect restores the settings defined by the server profile after the

server blade completes the next boot cycle.

After Virtual Connect assigns a server profile to a server, RBSU cannot modify the protocol configuration
(iSCSI/FCoE) for any NIC, including the NC551m, even if the NIC is not connected to a Virtual

Connect module. Any protocol configuration changes must be made before the server profile is

assigned to the server.

To boot properly from SAN when using Linux and VMware ESX 3.0.1 and ESX 3.0.2, change the

QLogic QMH2462 4Gb FC HBA connection option to 'point-to-point only' in the QLogic BIOS
configuration utility. The Emulex LPe 1105-HP 4Gb FC HBA does not require using the 'point-to-point'

connection option to boot properly from SAN.

If the VC domain is configured for double-dense server mode and a profile is assigned to an empty
server bay, a hot-plug installation of a single-dense server into that server bay results in the profile not

being activated. To recover the profile, unassign the profile, and then reassign it.

During a profile assignment, if the port number of an existing fabric has been changed to another
physical port, the fabric and the domain go into a failed state until the reconfiguration is complete. This

also might result in SNMP traps being sent to report the interim failed state.

Server profiles are associated with a specific enclosure device bay. After a profile is assigned, the Virtual

Connect Manager configures the server blade in that device bay with the appropriate MAC, PXE, WWN,

and SAN boot settings and connects the appropriate networks and fabrics. Server blades that have been

assigned a profile and remain in the same device bay do not require further Virtual Connect Manager

configuration during a server or enclosure power cycle. They boot and gain access to the network and fabric
when the server and interconnect modules are ready.
If a server blade is installed in a device bay already assigned a server profile, Virtual Connect Manager

automatically updates the configuration of that server blade before it can power on and connect to the

network.
If a server blade is moved from a Virtual Connect-managed enclosure to a non-Virtual Connect enclosure,

local MAC addresses and WWNs are automatically returned to the original factory defaults. This feature

prevents duplicate MAC addresses and WWNs from appearing in the data center because of a server blade

redeployment.

Creating server profiles

To create a new server profile, use the add profile command:

>add profile MyNewProfile

To copy the configuration from one profile to another profile, use the following command:

>copy ExistingProfile MyNewProfile

After an enclosure is imported into a Virtual Connect domain, server blades that have not been assigned a

server profile are isolated from all networks to ensure that only properly configured server blades are

attached to data center networks.