Enet-vlan – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 31

Advertising
background image

Command line 31

Item

Description

SpeedType is Custom)

MAX configured speed for the network in 100Mb increments.

Examples

->set enet-connection MyProfile 2

Network=NewNetworkName

Changes the associated network of an Ethernet connection

->set enet-connection RedProfile 1 Network=""

Sets a network connection to "Unassigned"

->set enet-connection GreenProfile 3 PXE=disabled

Disables PXE on an Ethernet connection

->set enet-connection MyProfile 1 SpeedType=Preferred

Modifies the Ethernet network connection to set the speed to "Preferred"

->set enet-connection MyProfile 1 SpeedType=Custom

Speed=2000

Modifies the Ethernet network connection to set the speed to 2Gb

Item

Description

show enet-connection

Display the Ethernet connections associated with the server profiles.

Syntax

show enet-connection [<ConnectionID>]

Parameter

ConnectionID (optional)

The ID of an existing Ethernet connection. The ID format is
<ProfileName:Port>. Use <ProfileName:*> to display all profile

Ethernet connections. Use "*" to display all connections in the domain.

Examples

->show enet-connection *

Displays all Ethernet connections in the domain

->show enet-connection Profile1:*

Displays all Ethernet connections of a profile named Profile1

->show enet-connection Profile1:1

Displays a specific Ethernet connection of a profile named Profile1

enet-vlan

Manage Ethernet VLAN configuration settings.
Supported actions: help, set, show

Item

Description

set enet-vlan

Modify general Ethernet VLAN configuration settings.

Syntax

set enet-vlan [-quiet][SharedServerVLanId=<true|false>]

[PrefSpeedType=<Auto|Custom>] [PrefSpeed=<speed>]

[MaxSpeedType=<Unrestricted|Custom>] [MaxSpeed=<speed>]

[VlanCapacity=<Legacy|Expanded>]

Option

quiet

This option suppresses user confirmation prompt, and is typically used in

automated scripting scenarios.

Properties

SharedServerVLanId

(optional)

Enables or disables the option to force server ports connected to multiple VC

Ethernet networks to use the same VLAN mappings as those used by

corresponding shared uplink sets. Valid values include "true" and "false".

Advertising