Introduction 6

Introduction

What's new

The command line interface user guide contains the following changes for VC 3.70/3.75:

•

The VC CLI displays the real WWN and MAC addresses in the following commands when the server

profile is assigned:

o

show all

o

show enet-connection

o

show fc-connection

o

show fcoe-connection

o

show iscsi-connection

o

show profile <ProfileName>

o

show server-port <PortID>
This depends on whether the server-port corresponds to a Flex-10 adapter. The VC CLI only displays
physical WWN and MAC addresses for physical ports and leaves the fields blank for virtual/Flex

ports.

•

Modified the following commands to allow for a "Disabled" speed type:

o

add enet-connection

o

set enet-connection

o

add iscsi-connection

o

set iscsi-connection

If the speed type is "Disabled", bandwidth is not allocated and the server port status is "Administratively
Disabled".

•

Modified the show config command to use bulk commands to enhance performance

•

Added the Type property to the add fabric command to allow the specification of a FabricAttach

or DirectAttach fabric for FlexFabric modules

•

Added the NoFlood property to the set igmp command to allow or prevent the flooding of

unregistered multi-cast packets

•

Modified the show ssl-certificate * output to display the new data fields when they are set in

the installed certificate

•

Modified the save ssl-csr command to include additional certificate data fields
Additionally, if the existing key is 1024 bits, a 2048 bit key and certificate will be generated before the
certificate signing request (CSR) is created.

•

Modified the reset statistics command to reset per-port statistics for the specified port ID and its

associated subports

•

Modified the show statistics command to display common statistics for the subport