NonStop AutoTMF Software Commands

HP NonStop AutoTMF Software User’s Guide429952-014

6-35

ALTER GLOBAL

parameter-and-value

ATMF { ON | OFF }

enables or disables automatic transaction processing. The default is ON if the
system has been licensed to use NonStop AutoTMF software.

ATMFABENDNOAUDIT { ON | OFF }

specifies that NonStop AutoTMF software will abend a program that attempts
to OPEN a database file that has been configured explicitly with the
COMMONTX, SEPARATETX or NOTX attribute but is NOT audited at the time
of the OPEN.

The default is OFF.

ATMFAUDITRENAME { ON | OFF }

enables or disables renaming of audited files.

The default is OFF.

ATMFAUTOCOMMIT n [ SEC[ONDS] | MIN[UTES] ]

instructs NonStop AutoTMF software to commit all outstanding automatic
transactions and abend the process if any exceeds the specified time limit.

n is a number between 5 and 500 minutes or the equivalent number of
seconds. The value is stored internally in minutes; so if seconds is entered,
some rounding of the value may occur. The default unit is minutes.

If n = 0, AUTOCOMMIT is disabled.for all files and programs.

If a program fails to unlock a record and prevents NonStop AutoTMF software
from committing automatic transactions, the non-committed updates are
eventually lost because the TMF AUTOABORT timer will cause the abort of the
long running transaction.

To prevent such data loss, AUTOCOMMIT should be set to a value that is less
than the TMF AUTOABORT timer value: AUTOABORT minus 5 minutes is
recommended because there may be some latency in detecting the long
transactions.

{ SECURETRACE { ON | OFF }

}

{

}

{ [SWAP]KMSF { ON | OFF }

}

{

}

{ SWAPVOL[0] local-disk-volume

}

{ SWAPVOL1 local-disk-volume

}

{ SWAPVOL2 local-disk-volume

}

{ SWAPVOL3 local-disk-volume

}