HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 141

Advertising
background image

Virtual Connect server profiles 141

Column name

Description

Port

Relative order of the Fibre Channel port on the server receiving the profile

Connected to

Bay number of the VC-FC module to which the port is connected

FC SAN name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the Fibre Channel module port connected to the server HBA port

Port speed

Speed of the VC-FC module port connected to the server HBA port

WWPN

Type of WWN address assignment configured for the Virtual Connect
domain

Action

Perform delete operations

FCoE HBA Connections

Port

Relative order of the port on the server receiving the profile

Connected to

Bay number of the FlexFabric module to which the port is connected

FC SAN name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the Fibre Channel module port connected to the server HBA port. The
FCoE downlink port status of LOGGED-IN means that the Ethernet virtual port

is in a linked state and that there is at least one FCoE login. The FCoE

downlink port status of NOT-LOGGED-IN means that either the Ethernet
virtual port is in an unlinked state or that there are no FCoE logins.

Port speed

Requested speed for the FlexFabric connection

WWPN

Type of WWN address assignment configured for the Virtual Connect

domain

MAC

Type of MAC address assignment configured for the Virtual Connect domain

Action

Perform delete operations

Assign Profile to Server Bay

Power

Icon indicates if the server blade is powered on or off (when a server blade is

selected).

Server Bay Assignment

Displays the enclosure name, bay number, and type of server blade

S/N

Serial number of the server blade in the device bay

Model

Model name of the server blade in the device bay

Status

Status of the server blade in the device bay

UID

Icon indicates if the server blade UID is on or off.

* Only Flex-10 NICs and FlexFabric NICs connected to Flex-10 modules and FlexFabric modules are able to set the

transmit bandwidth allocation. Other parts are restricted to the actual physical speed (1Gb).

The following table describes the available actions in the Define Server Profile screen. Clicking another link
in the pull-down menu or left navigation tree causes current edits that have not been applied to be lost.

Task

Action

Change a profile name

Edit a name in the Profile Name field.

Associate a network access
group

Click the Network Access Group pull-down arrow, and then select a network

access group.

Select to use server factory
defaults for Ethernet MAC

addresses

Select the Advanced Profile Settings checkbox, and then select the Use Server
Factory Defaults for Ethernet MAC addresses checkbox.

Select to use server factory
defaults for Fibre Channel

WWNs

Select the Advanced Profile Settings checkbox, and then select the Use Server
Factory Defaults for Fibre Channel WWNs checkbox.

Select to use factory defaults for
serial numbers

Select the Advanced Profile Settings checkbox, and then select the Use Server

Factory Defaults for Serial Numbers checkbox.

Advertising