Virtual Connect server profiles 161

Column name

Description

Allocated Bandwidth

Allocated bandwidth of the port. See "Bandwidth assignment (on page

131

)."

Boot Setting

Enables or disables offload or boot on the network connection. Valid values

are DISABLED, PRIMARY, (SECONDARY), and USE-BIOS. For more
information, see "Creating iSCSI connections (on page

144

)." After selecting

an option, you must click outside the grid to complete the selection. This is the

same procedure that is followed when selecting a fabric or network for an FC
or Ethernet connection, respectively. Once the Boot Setting column has been

completed, you can then edit the Target Port Name and LUN.

MAC

The MAC address assigned to the port, or "Server Factory Default" if not

using VC-assigned MAC addresses

Mapping

Server hardware mapping assignment. See "iSCSI and FCoE port
assignments (on page

130

)."

Action

Delete a connection. Connections can be removed starting with the last

connection in the list.

FC HBA Connections

Port

Relative order of the Fibre Channel port on the server receiving the profile

Connected to

Bay number of the VC-FC module to which the port is connected

FC SAN Name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the Fibre Channel module

Port speed

Speed of the VC-FC module port connected to the port

WWPN

The World Wide Port Name assigned to the port, or "Server Factory Default"
if not using VC-assigned MAC addresses

Action

Delete a connection. Connections can be removed starting with the last

connection in the list.

FCoE HBA Connections

Port

Relative order of the FCoE port on the server receiving the profile

Connected to

Bay number of the VC module to which the port is connected

FC SAN Name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the VC module

Port Speed

Speed of the VC module port connected to the port

Allocated Bandwidth

Allocated bandwidth of the port. See "Bandwidth assignment (on page

131

)."

WWPN

The World Wide Port Name assigned to the port, or "Server Factory Default"

if not using VC-assigned MAC addresses

MAC

The MAC address assigned to the port, or "Server Factory Default" if not

using VC-assigned MAC addresses

Mapped

Server hardware mapping assignment. See "iSCSI and FCoE port
assignments (on page

130

)."

Action

Delete a connection. Connections can be removed starting with the last

connection in the list.

* Only Flex-10 NICs and FlexFabric NICs connected to Flex-10 modules and FlexFabric modules are able to

set the transmit bandwidth allocation. Other parts are restricted to the actual physical speed (1Gb).
The following table describes the available actions in the Edit Server Profile screen. Clicking another link in