HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 90

Advertising
background image

Virtual Connect networks 90

Field name

Description

within VCM.

Labels

A network can have up to 16 user-defined labels to group and identify the

network within VCM.

Smart Link (on page

75

)

To enable Smart Link, edit the network settings after the network is

created. The checkbox is not available until an uplink is added to the

network.

Private Network ("

Private Networks

" on

page

75

)

Select whether to designate (checked) or not designate (unchecked) this
network as a private network.

Enable VLAN Tunneling ("

VLAN

Tunneling Support

" on page

75

)

Select whether to enable (checked) or disable (unchecked) VLAN

Tunneling. If enabled, VLAN tags for this network are passed through the

domain without any modification. If disabled, all tagged frames are
discarded. If this network is assigned to a server profile or associated with

a shared uplink set, this option cannot be modified.

External Uplink Ports

Use Shared Uplink Set

Enables the selection of a shared uplink set to be used as the uplink port
for this network. For more information, see “Shared uplink sets and VLAN

tagging (on page

74

)."

Port

Network port locations (enclosure, bay, and port numbers)

Port Role

Applicable when Failover Connection Mode is selected. The port can be
designated as Primary or Secondary.

Port Status

Shows the link status, link speed, and connectivity of the port. If the port is

unlinked and no connectivity exists, the cause is displayed. For more

information about possible causes, see "Port status conditions (on page

208

)."

Connector Type

Displays the type of connector on the port; for example, RJ-45

Connected to

If the port is connected to a switch that supports LLDP, the switch MAC

address and switch port appear. A link is provided to obtain more
information about the far-end switch port.

PID

When selected, sets/clears the port identifier color as blue on the VC-Enet

module to aid in the location of the specific uplink. The PID status for the

overall network also appears.

Speed/Duplex

Pull-down menu to specify the speed and duplex (where applicable) of the

uplink port. Half-duplex operations are not supported by the VC-Enet

module.

Network Access Groups

Displays the Network Access Groups that include this network.

The following table describes the available actions in the Define Ethernet Network Screen. Clicking another
link in the pull-down menu or left navigation tree causes current edits that have not been applied to be lost.

Task

Action

Define network color

Select a color from the Color pull-down menu.

Define network label

Type a label in the Labels field, and then press Enter. A network can have

up to 16 labels. Labels cannot contain spaces and are limited to 24

characters.

Enable Smart Link on the network being
defined

Select the Smart Link checkbox. The checkbox is not available until an
uplink is added to the network.

Designate the network as a private

network

Select the Private Network checkbox.

Enable VLAN tunneling

Select the Enable VLAN Tunneling checkbox.

Set a custom value for preferred link

Select the Advanced Network Settings checkbox. For more information,

Advertising