Interconnect bay summary screen (ethernet module), Interconnect bay summary screen (ethernet, Module) – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 185

Advertising
background image

Virtual Connect modules 185

FC modules in multi-enclosure double dense domains
When using VC-FC modules, multi-enclosure double dense domains require similar and compatible
VC-FC modules in bays 5, 6, 7, and 8 in all enclosures. If a multi-enclosure double dense configuration

contains incompatible VC-FC modules in bays 5, 6, 7, or 8 in either the local or remote enclosures,
some or all of the compatible VC-FC modules in the remote enclosures might be designated

INCOMPATIBLE after import.
Corrective action:

a.

Replace incompatible VC-FC modules with similar and compatible VC-FC modules in bays 5, 6, 7,
and 8 in all enclosures.

b.

Power cycle any VC-FC module that still remains in an INCOMPATIBLE state.

Interconnect Bay Summary screen (Ethernet module)

This screen provides a summary of the interconnect module status and port information. To remove a module,

see "Interconnect module removal and replacement (on page

209

)."

The following table describes the rows within the Interconnect Bay Status (VC-Enet Module) table in the Bay

Summary screen.

Row

Description

Overall Status

Represents the worst condition of OA Reported Status, VC Status, and OA

Communication Status

Hardware Status

Component health status from the Onboard Administrator

VC Status

Component health status from the Virtual Connect Manager

OA Communication Status

Current Virtual Connect Manager to Onboard Administrator communication
state

Rack Name

Name of the enclosure rack (assigned through the Onboard Administrator)