Hp bladesystem c-class enclosures, Enclosure serial numbers, Using multiple enclosures – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 49

Advertising
background image

HP BladeSystem c-Class enclosures 49

HP BladeSystem c-Class enclosures

Enclosure serial numbers

The enclosure serial number is used by the Virtual Connect Manager to associate a Virtual Connect domain
with a particular enclosure. The enclosure serial number can be altered for maintenance purposes, such as
replacement of the enclosure midplane. For more information, see SET ENCLOSURE SERIAL_NUMBER in

the HP BladeSystem Onboard Administrator Command Line Interface User Guide on the Installing tab of the

HP BladeSystem Technical Resources website (

http://www.hp.com/go/bladesystem/documentation

).

Enclosure serial numbers are unique as shipped from the factory, and must remain unique for proper

Virtual Connect Manager operation. Use care when altering the enclosure serial number to ensure that
serial numbers are unique within the management network.

After an enclosure is imported into a domain, do not change the serial number. The enclosure must have
the enclosure serial number that was present when imported initially. It cannot be replaced with an

enclosure that has a different serial number.

In the event of an enclosure failure, the replacement enclosure must have the serial number set to that of
the failed enclosure before it is placed into the VC domain.

If you are moving interconnect modules, OA modules, and server blades from one enclosure to another,
you must first save the VC configuration, then move the OAs to the new enclosure and power on the

OAs. After the OAs are powered up and you can log in, then place the interconnect modules in the

enclosure and power them on. After you can log in to VCM, restore your configuration. After the

configuration is restored, move the server blades to the new enclosure. If the server blades are already
in the new enclosure, the servers are required to be powered off when the VC configuration is restored

in the new enclosure.

In an existing VC domain, if the enclosure serial number is changed from the OA with the set enclosure

serial-number command, HP recommends that all the VC Ethernet modules be reset through the OA so that
the new enclosure number is propagated to all the modules in the enclosure. Do not attempt to replicate

domains within the environment using the save/restore mechanisms. This can create serious errors within the

replicated domain and the original domain.

Using multiple enclosures

Multiple enclosure support enables up to four c7000 enclosures to be managed within a single Virtual

Connect domain for a total of 128 servers, if double-dense support is enabled while using the Domain Setup

Wizard. There are 16 half-height or 8 full-height server bays in a c7000 enclosure. A combination of

full-height and half-height servers can be used in the same enclosure.
Multiple enclosure domains are not supported on c3000 enclosures. The VC-Enet or FlexFabric modules use

stacking cables between enclosures so that network traffic can be routed from any server Ethernet port to any

uplink within the VC domain. Since FC does not support stacking, the VC-FC or FlexFabric module FC uplinks

on the same bay of all enclosures must be connected to the same FC switch to enable profile mobility.
The management interfaces for all enclosure Onboard Administrators and VC modules within the same VC

domain must be on the same lightly loaded subnet and highly reliable network. Overloads or loss of

Advertising