Vlan capacity – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 86

Advertising
background image

Virtual Connect networks 86

You can tunnel VLAN tags and map VLAN tags in the same domain. As of VC 3.30, tunneling and mapping

is configured at the network level, not at the domain level. Server VLAN tunneling is supported only on
networks with dedicated uplinks and cannot be used with shared uplink sets.
Server VLAN tagging support
When the 'Force server connections to use same VLAN mappings as shared uplink sets' check box is

selected, server ports connected to multiple VC Ethernet networks are forced to use the same VLAN mappings
as those used for the corresponding shared uplink sets. This action forces all server connections mapped to

multiple networks to be linked to a shared uplink set. Server administrators cannot override this selection

when creating or editing a profile. When this check box is selected, server network connections can only be

selected from a single shared uplink set.
When the 'Force server connections to use same VLAN mappings as shared uplink sets' check box is not
selected, server network connections can be selected from any VC Ethernet network and the external VLAN

ID mappings can be manually edited. However, administrators must ensure that no server connection VLAN

ID conflict exists.
The 'Force server connections to use the same VLAN mappings as shared uplink sets' check box can be
selected if no server profile connections are assigned to multiple networks that are not linked to a shared

uplink set.

VLAN Capacity

Virtual Connect imposes certain limits on the number of networks (VLANs) in the domain and the server

connections carrying multiple VLANs. In a VC domain that does not contain legacy (1/10Gb) VC Ethernet

modules, these restrictions can be relaxed to provide support for more VLANs and enhance the flexibility of
mapping VLANs to server connections. When VCM detects that no legacy modules are present in the

domain, it enables the selection of a new domain mode that expands the VLAN capacity. The increase in the

number of VLANs per domain, in addition to the flexibility of allocating VLANs among the server connections

for a physical port, provides you with more options when configuring a Virtual Connect environment.

CAUTION:

If VCEM is managing the domain, be sure that the VCDG containing the domain is

running at a firmware mode of 3.30 or higher before applying VLAN capacity changes. Failure

to do so requires removal of the domain from the VCEM VCDG.

Legacy VLAN capacity
This mode has the same limits as previous releases of Virtual Connect. There is a limit of 320 VLANs per

Ethernet module and 128 VLANs per shared uplink set. Every VLAN on every uplink counts towards the 320
VLAN limit. If a shared uplink set is comprised of multiple uplinks, each VLAN on that shared uplink set is

counted multiple times. In addition, each server connection is limited to 28 VLANs. If less than 28 VLANs are

used on a server connection, the remaining capacity is not made available to other server connections on the

same physical server port. All VC Ethernet modules are supported.
Expanded VLAN capacity
This mode allows up to 1000 VLANs per domain. The number of VLANs per shared uplink set is restricted to

1000. In addition, up to 162 VLANs are allowed per physical server port, with no restriction on how those

VLANs are distributed among the server connections mapped to the same physical server port. There is also

a limit of 162 VLANs per server connection. However, care must be taken not to exceed the limit per physical
server port. For example, if you configure 150 VLAN mappings for a server connection (FlexNIC-a) of a

Flex-10 physical server port, then you can only map 12 VLANs to the remaining three server connections

(FlexNIC-b, FlexNIC-c, and FlexNIC-d) of the same physical server port. If you exceed the 162 VLAN limit,

the physical server port is disabled and the four server connections are marked as Failed.