Error check, First error check, Second error check – HP XP Array Manager Software User Manual

Page 98: Available configuration values for the [ldev] tag

Advertising
background image

Table 18 Available Configuration Values for the [LDEV] Tag

Column

Item

Available Value

1st, 11th (Index)

Ldkc

00

2nd, 12th (Index)

Cu

00 - FE. Set with hexadecimal numbers in one or two

digits.

3rd, 13th (Index)

Ldev

00 - FF. Set with hexadecimal numbers in one or two

digits.

4th, 14th

Cmd. Dev
(Command Device)

Enable or Disable (The default when the spreadsheet is

exported)
ON or OFF are also available as the set value when you

write the spreadsheet.

5th, 15th

Cmd. Sec
(Command Device

Security)

Enable or Disable (The default when the spreadsheet is

exported)
ON or OFF are also available as the set value when you

write the spreadsheet.

6th, 7th,
16th, 17th

Blank

Error Check

First Error Check

The first error check is performed when the spreadsheet file is imported. The first error check verifies

that the spreadsheet is properly formatted. If there is an error, the spreadsheet is rejected, and an error

message is displayed. Errors detected at this first check include the following:

The first row of the spreadsheet (the declaration line) is not correctly written, or the

stated program product is not installed. For more information on the declaration line, see

Spreadsheet Declaration

” on page 87.

The spreadsheet file is not in text file format (the file is a binary file).

There is no function tag in the spreadsheet. For more information on the function tag, see

Function Tags

” on page 87.

The file name is incorrect (for example, the extension is not .spd, or the file name exceeds the

maximum number of letters).

The number of letters in a row exceeds 200.

The number of rows in a spreadsheet exceeds 400,000.

Second Error Check

In the second check, the spreadsheet settings are verified. Any errors found are displayed on the

Error Information list. This second check is performed before the Apply button becomes available.

Figure 48

on page 99 shows the flow of the second check.

The second error check consists of two different types of the checks. These checks are shown in

Figure 48

on page 99 as the Level 1 and Level 2. The Level 2 check is performed only when no error is

found by the Level 1 check. Each level of the check of the second error check detects the following errors:

Level 1 check (the format and parameters are checked):
• A function tag is not supported.
• A setting value is incorrect or omitted.
• The setting range is incorrect. The correct ranges are as follows:

LDKC:00

CU:00 - FE

98

Performing LUN Manager Operations Using Configuration File Loader

Advertising