85

First Port Address

Switch Fibre Channel address

World Wide Name

Switch World Wide Name

Serial Number

Number assigned to each chassis

Reason for Status

Reason for the operational state

Vendor

Switch manufacturer

MAC Address

Media Access Control address

Negotiated Domain ID

Domain ID currently being used by the fabric

Configured Domain ID

Domain ID, defined by network administrator

Domain ID Lock

Domain ID lock status. Prevents (True) or permits (False) dynamic

domain ID reassignment.

Number of Ports

Number of physical ports on the switch

Operational State

Switch operational state: Online, Offline, Diagnostic, Down

Administrative State

Current switch administrative state

Configured Admin State

Administrative state that is stored in the switch configuration

Beacon Status

Switch LEDs are blinking (On) or not blinking (Off).

Status Group
Operational State

Switch operational state: Online, Offline, Diagnostic, Down

Administrative State

Current switch administrative state

Configured Admin State

Administrative state that is stored in the switch configuration

Beacon Status

Beacon status. Switch LEDs are blinking (On) or not blinking (Off).

Reason for Status

Reason for the operational state

Temperature

Internal switch temperature °C

Fan 1 Status

Fan 1 operational status (dual power supply model only)

Fan 2 Status

Fan 2 operational status (dual power supply model only)

Fan 3 Status

Not applicable

Power Supply 1 Status

Power supply 1 operational status

Power Supply 2 Status

Power supply 2 operational status (dual power supply model only)

Temperature Failure Port

Shutdown

Non-configurable (always enabled for this switch). All ports are shut

down when the switch temperature exceeds the Failure Temperature.

Warning Temperature

Non-configurable temperature threshold, above which a warning

condition alarm is generated

Failure Temperature

Non-configurable temperature threshold, above which a failure

condition alarm is generated

POST Status

Current diagnostic state of the switch

POST Fault Code

Code value for the last recorded diagnostic test result recorded on the

switch

Test Status

Current diagnostic test status of switch

Table 11

Switch data window fields (continued)

Field

Description

Advertising