Boot BIOS 7-3

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: Compaq StorageWorks 64-Bit PCI-To-Fibre Channel Host Bus Adapter User Guide Comments:

Part Number: AA-RKPDA-TE 173941-001 File Name: H-CH7 BOOT BIOS.DOC Last Saved On: 12/8/99 11:04 AM

Use all defaults and run in read only mode (y/n) [y] ?n
Enter execution time limit in minutes (1:65535) [10] ?
Include performance statistics in performance summary (y/n) [n] ?
Display hard/soft errors (y/n) [n] ?
Enter IO queue depth (1:8) [4] ?
***Available tests are:

1. Basic function

2. User defined

Use the basic function test 99.9% of the time. The user defined test is for special
problems only.
Enter test number (1:2) [1] ?2

In the user defined test, you may define up to 20 commands.
They will be executed in the order entered.
The commands will be repeated until the execution time limit expires.

CAUTION: If you define write commands, user data will be destroyed.

Enter command number 1 (read, write, quit) [] ?write.
Enter data pattern number 0 = ALL, 19 = USER_DEFINED, (0:19) [0] ?
Enter starting lbn for this command ?0
Enter the IO size in 512 byte blocks for this command (1:64 [] ?64
Enter command number 2 (read, write, quit) [] ?quit.
Drive unit numbers available for testing on this HBA include:
0.
Enter unit number to be tested ?0.
Unit 0 will be write enabled.
Do you wish to add this unit (y/n) [n] ?y.
Unit 0 successfully allocated for testing.
Maximum number of units are now configured.
DILX testing started at : 20:06:34.
Test will run for 10 minutes.
Type ^G to get a current performance summary.
Type ^C to terminate the DILX test prematurely.
Type ^Y to terminate the DILX prematurely.

DILX terminated prematurely by user request
DILX aborting, abort code 8
HSG BOT3(9600) >