Troubleshooting 4-9

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: Compaq StorageWorks 64-Bit PCI-To-Fibre Channel Host Bus Adapter User Guide Comments:

Part Number: AA-RKPDA-TE 173941-001 File Name:

E-CH4 TROUBLESHOOTING.DOCe-ch4 Troubleshooting.doc

Last Saved On:

12/22/99 10:10

AM12/20/99 6:07 PM

Private Loop Device Mapping

In a private loop environment (FCAL, no switch), devices are initially created
based on a fixed address ordering. Once created (at boot), the devices
continue to be tracked based on:

– WWPN:

HardAddress=0;MapNodeName=0

– NodeName:

HardAddress=0;MapNodeName=1

– D_ID:

HardAddress=1; (MapNodeName=don’t care)

This section identifies the initial fixed mapping between the Windows NT
bus/target/lun and a fibre channel native address (AL_PA/SEL_ID). There are
two potential mappings based on a registry parameter [ScanDown=0 (driver
default); use *, ScanDown=1;].

The index into Table 4-5 can be derived by:

#define TARGETS_PER_BUS 32

i = (Srb->PathId > 0) ? Srb->PathId-1 : 0; //Bus 0 = dummy bus nodeInx = ((I *
(TARGETS_PER_BUS-1)) + Srb->TargetId;

Table 4-5

Current Private Loop Device Mapping

Bus #
0

Target#
0-31

Lun#
0-7

*AL_PA
None

*SEL_ID
None

**AL_PA
None

**SEL_ID
None

1***

0

0-7

0x01

0x7D

0xEF

0x00

1

0-7

0x02

0x7C

0xE8

0x01

2

0-7

0x04

0x7B

0xE4

0x02

3

0-7

0x08

0x7A

0xE2

0x03

4

0-7

0x0F

0x79

0xE1

0x04

5

0-7

0x10

0x78

0xE0

0x05

6

0-7

0x17

0x77

0xDC

0x06

* Use this translation if registry ScanDown = 0 (default)

** Use this translation if registry ScanDown = 1

*** If MapBus0=1;, then device addressing starts with Bus #0, not #1