HP Workstation xw8000 User Manual

Page 107

Advertising
background image

4-41

Using the Command Line Interface

enclosure prepare slot {enclosure} {slot}

Prepares a device in a slot for insertion/removal.

Parameters

{enclosure}—ID associated with the enclosure
management device on which to prepare a slot.

{slot}—Unit number associated with the slot.

enclosure set alarm [/on{=boolean}] {enclosure}

Turns the audible alarm on or off.

Parameters

{enclosure}—ID associated with the enclosure
management device whose audible alarm to set.

Switches

/on—Specifies whether to turn the audible alarm on or off.

enclosure set door [/lock{=boolean}] {enclosure}
{door}

Locks or unlocks a specific door on a specific enclosure.

Parameters

{enclosure}—ID associated with the enclosure
management device on which to lock the door.

{door}—Unit number of the door.

Switches

/lock—Specifies whether to lock the door associated with
the unit number.

enclosure set fan [/off{=boolean}] {enclosure}
{fan} [{speed}]

Sets the speed of a specific fan.

Parameters

{enclosure}—ID associated with the enclosure
management device on which to set the speed of a fan.

{fan}—Unit number associated with the fan.

{speed}—Speed at which to set the fan.

Switches

/off —Specifies whether to turn off the fan.

UG.book Page 41 Saturday, October 26, 2002 12:08 PM