Select the desired stripe size. The allowable stripe sizes are 16,
32, and 64 KB (the default). For RAID 50 arrays, 64 KB is the
only stripe size supported by ACU. The default stripe size gives
the best overall performance in most network environments.

5

Specify whether you want to enable read caching for the array.

This option should always be enabled to optimize performance,
unless your application is doing completely random reads,
which is unlikely.

6

Specify if you want to enable write caching for the array.

Note:

By design, some controllers do not allow the use of

write caching. In such cases, the controller will not activate
write caching, regardless of the write cache setting. If this
is the case a message will be displayed that tells you the
settings have been recorded but have no effect.

Write caching options (if supported) consist of the following:

Enable when protected

—If supported, enables the write

cache only when a battery is present and the battery’s charge
status is OK.

Enable always

—If supported, enables the write cache even

if no battery is present or the battery’s charge status is not
OK. Note that setting an array’s write cache property to
Enable

always might result in data loss or corruption if

power to the controller is lost when no battery is present or
the battery loses its charge.

Disable

—Disables use of the write cache.

7

When you are finished, press Done.