Using the scsi configuration utility, Using the scsi configuration utility 2-13 – HP Workstation xw8000 User Manual

Page 29

Advertising
background image

2-13

Using Adaptec RAID Configuration

The Ctrl-B option in ACU moves any array to be array 00.
Using this option repeatedly allows any boot order to be
chosen.

The default is Disabled.

Physical Drives Display during POST

— The default is

Disabled.

CD-ROM Boot Support

— The default is Enabled.

Removable Media Devices Support

— The default is

Enabled.

Alarm Control

— The default is Enabled.

You cannot set the following options:

NVRAM State

— Displays the current status of the NVRAM

cache. This option is available only for controllers that have
a battery and is for display only. In normal operation it will
display Clean.

Controller Memory Size

— Displays the amount of memory

installed on the controller.

Using the SCSI Configuration Utility

The SCSI Configuration Utility enables you to modify the SCSI
Channel Interface Definitions and SCSI Device Configuration
Options.

To access the SCSI Configuration Utility:

1

When you turn on or reboot your system, press Ctrl+A to access
the Adaptec RAID Configuration (ARC) utilities when
prompted by the following message:

Press <Ctrl><A> for Adaptec RAID Configuration Utility

2

If multiple controllers are installed, select the controller you
want to configure and press Enter.

3

From the ARC menu, select SCSISelect Utility.

The Controller Configuration and SCSI Configuration menu
options are displayed.

4

Select SCSI Configuration.

UG.book Page 13 Saturday, October 26, 2002 12:08 PM

Advertising
This manual is related to the following products: