Adaptec SCSI RAID 2120S/2200S Software User’s Guide

It is only possible to create tasks for arrays or drives. If you select
Tasks

for a channel, controller, or the system, all relevant tasks will

be displayed.

When Adaptec Storage Manager is installed a scheduled task is
created to perform a weekly background consistency check of all
hot spares in the system. This task can be seen by clicking Tasks
when it is blue, that is when nothing is selected.

New Tasks Tab

Allows you to create new tasks for an array or a drive. New Tasks
can either be run immediately, or scheduled to run at a later time.
Available tasks are Verify, Verify with Fix, and Clear. An
explanation of the impact of each task is given below.

Drive

Verify—

Performs a test of the entire drive to ensure that

there are no problems. Any bad blocks found are not
repaired.

Verify with Fix—

Performs a test of the entire drive to

ensure that there are no problems. Any bad blocks found are
repaired.

Clear—

Erases all data on the drive. Any data previously on

the drive is not recoverable, and if all or part of the drive is
used in an array, data integrity of the array will be
compromised.

Array

Verify

—Performs a test of the entire array to ensure that

data is consistent. Any inconsistency found is not repaired.

Verify with Fix

—Performs a test of the entire array to

ensure that data is consistent. Any inconsistency found is
repaired.

Clear

—Erases all data on the array. Any data previously on

the array is not recoverable.