Configuring serial port, Using tcp/ip over ethernet management port – HP Lights-Out 100 Remote Management User Manual

Page 9

Advertising
background image

a.

Press the down arrow (

↓) key to scroll to IPMI. Press the Enter key.

b.

Set Serial Port Assignment to BMC.

c.

Set Serial Port Switching to Enabled.

d.

Set Serial Port Connection Mode to Direct.

On DL160 G6, DL160se G6, DL170h, DL180 G6, SL160z G6, SL170z G6, SL 170s G6,
SL2x170z G6 servers and DL165 and SL165z G7 servers:
a.

Press the down arrow (

↓) key to scroll to IPMI Configuration. Press the Enter key.

b.

Scroll down to Serial Port Configuration.

c.

Set Serial Port Assignment to BMC.

d.

Set Serial Port Connection Mode to Direct.

5.

Press the F10 key to save and exit.

Configuring serial port

1.

Power on the server by pressing the Power On/Off button on the front panel.

2.

When POST displays the message, ROM-Based Setup, press the F10 key. If the server has
an administrator password configured, the system prompts you to enter the password. If
the server does not have a password configured, the main screen of the BIOS Setup Utility
appears.

3.

Press the right arrow (

→) key to navigate to the Advanced menu.

4.

Press the down arrow (

↓) key to scroll to IO Device Configuration, or, if you are using SL160z

G6 servers or DL165 or SL165z G7 servers, scroll to Super IO Configurations. Press the Enter
key.

5.

Set Embedded Serial Port to 3F8/IRQ4.

6.

From the Remote Access Configuration, configure the BIOS Serial Console as follows:

BIOS Serial Console-Enabled

EMS Support-Disabled (for ML150 G6)

Base Address/IRQ-3F8h, 4

Serial Port Mode-9600 8, n, 1

Flow Control-None

Redirection after BIOS/POST-Enabled

Terminal Type-VT100

7.

For DL 165 G7 and SL 165 G7 servers, from the Remote Access Configuration, configure the
BIOS Serial Console as follows:

BIOS Serial Console Port-Enabled

BIOS Serial Console Port Baud Rate-[115200 8, n, 1]

Redirection after BIOS POST-Always

Terminal Type-ANSI

VT-UTF8 Combo Key Support-Enabled

8.

Review the serial port settings, and make sure the settings match the serial port
communications software settings used to connect to LO100.

9.

To return to the previous screen, press the Esc key, or to save the changes and exit Setup,
press the F10 key.

Using TCP/IP over Ethernet management port

You can configure LO100 LAN port access using two different Ethernet ports: the dedicated
10/100 LO100 management port or through a side-band connection using the server embedded
NIC. The side-band, shared, or UMP options utilize one server Ethernet port for both server

Using TCP/IP over Ethernet management port

9

Advertising