100 example of the flashcpy withdraw command – HP XP Business Copy Software User Manual

Page 155

Advertising
background image

ShadowImage for z/OS user guide 155

5.

Execute the FLASHCPY ESTABLISH command, specifying the RESTORE parameter and reversing the

S-VOL and the T-VOL.

If the S VOL before performing Reverse Restore is updated, only the data of the updated part of the S VOL

(differential data) before performing Reverse Restore will be copied to the T VOL. When the T VOL before

performing Reverse Restore is updated, only the data of the updated part of the T VOL will be copied from

the S VOL after performing Reverse Restore.
Note: Set the CHANGERECORDING parameter to YES to maintain the relationship after copying process

is completed and to manage the differential data between the S VOL and the T VOL. If

CHANGERECORDING parameter is not specified, the relationship will be deleted after copying process is

completed.

Withdrawing FlashCopy® Mirror Version 2 Pairs: FLASHCPY WITHDRAW

To delete a FlashCopy Mirror Version 2 pair by using the ICKDSF FLASHCPY WITHDRAW command:

1.

If the OS of the host server is MVS, specify the JCL statement in the DDNAME parameter or specify the

S-VOL device number of the FlashCopy Mirror Version 2 pair that you want to delete for the

UNITADDRESS parameter.

2.

Specify SYSNAME of the ASSGN system control statement in the SYSNAME parameter if the OS of the

host server is VSE.

3.

Specify the CU number, LDEV number, and device number of the T VOL in the TARGETVOL parameter.

4.

See

Table 70

on page 150 and specify any other necessary parameters.

5.

Execute the FLASHCPY WITHDRAW command.

Figure 100

Example of the FLASHCPY WITHDRAW Command

NOTE:

When the FLASHCPY WITHDRAW command is executed, all the dataset relationships existing in

the specified volume will be deleted.

The FLASHCPY WITHDRAW command and the applicable combinations are predetermined. If you specify

any other parameter than the predetermined combinations, the FLASHCPY WITHDRAW command is

normally ended without executing any process.

Table 72

on page 155 describes the parameters of the

FLASHCPY WITHDRAW command and the applicable combinations.

Table 72

Avoiding Abnormal Ending of the ICKDSF Commands (for FlashCopy Mirror Version 2)

FLASHCPY ESTABLISH UNIT(X'7001') TARGETVOL(X'00',X'00',7000) RESTORE

FLASHCPY WITHDRAW UNIT(X'7000') TARGETVOL(X'00',X'01',7001) MODE(COPY)

Parameter

Background copying

DDNAME, SYSNAME,

UNITADDRESS

TARGETVOL

MODE

Executed or not?

Relationship after

completion

S-VOL

T-VOL or some other

volume

COPY

YES

Maintained when

CHANGERECORDING

= YES
Released when

CHANGERECORDING

= NO

S-VOL

T-VOL

NOCOPY or not

specified

NO

Released