HP XP LUN Configuration and Security Manager Software User Manual

Page 12

Advertising
background image

12

LUN Manager for the XP10000/XP12000

00:01, and 00:02. LU paths are defined between the two hosts in the hg-lnx group and the three logical

volumes.

Figure 1

LU paths configuration in a Fibre Channel environment

LUN Manager lets you define paths between a single server host and multiple LUs. In

Figure 1

, both hosts

in the hg-lnx host storage domain can access the three available LUs.
LUN Manager lets you define paths between multiple server hosts and a single LU. In

Figure 1

, the LU

identified as CU-LDEV 00:00 is accessible to the two hosts in the hg-lnx host storage domain.
In

Figure 1

, the LUs associated with the hg-lnx domain are addressed by numbers 0 to 2. The address

number of an LU is referred to as the logical unit number (LUN). When HP StorageWorks Continuous

Access XP and other optional features manipulate LUs, they use LUNs to specify the LUs to be manipulated.
You can add, change, and delete LU paths when the system is operational. For example, if new disks or

server hosts are added to your disk array, you can add new LU paths. If an existing server host is to be

replaced, you can delete the corresponding LU paths before replacing the host. You do not need to restart

the system when you add, change, and delete LU paths.
If a hardware failure (such as a CHA failure) occurs, there is a chance that some LU paths are disabled

and some I/O operations are stopped. To avoid this, the system administrator can define alternate LU

paths. If one LU path fails, the alternate path takes over the host I/O.
In a Fibre Channel environment, up to 1,024 LU paths can be defined for one host storage domain. Up to

1,024 LU paths can be defined for one port.

NOTE:

You cannot define an LU path to LUN On Demand volumes or volumes reserved by Auto LUN XP.

Up to 256 host storage domains can be created for one Fibre Channel port. Up to 57,344 host storage

domains can be created for one disk array. The maximum number of ports per subsystem is 224.

Port

Host Storage Domain

Host Groups

Advertising
This manual is related to the following products: