Table 9 host mode options, Registering hosts in host groups, 9 host mode options – HP XP LUN Configuration and Security Manager Software User Manual

Page 24: Table 9

Advertising
background image

24

LUN Manager for the XP10000/XP12000

9.

Click OK. The settings are applied to the disk array.
The next step is to register hosts to the appropriate host group.

CAUTION:

Do not select options other than those listed in

Table 9

.

Registering hosts in host groups

Before you can set LU paths, you must register hosts in host groups. For example, if HP-UX and Windows

hosts are connected to a port, you must register them separately in two different host groups.
When registering a host, you can assign a nickname to the host bus adapter. If you assign a nickname,

you will be able to easily identify each host bus adapter in the LUN Manager main pane. Although

WWNs are also used to identify each host bus adapter, a nickname is more helpful because you can

name host bus adapters after the host installation site or the host owners.
When using nicknames, note the following:

A nickname can consist of up to 32 ASCII characters (letters, numerals, and symbols). You cannot use

the following characters for nicknames:

\ / : , ; * ? " < > | ~

You cannot use the space character for the first or the last nickname character.

Nicknames are case sensitive. For example, hp and HP are different nicknames.

To register hosts in a host group:

1.

Start LUN Manager, and display the LUN Manager pane (

Figure 7

).

Table 9

Host mode options

No.

Host Mode option

When to select option

2

VERITAS Database

Edition/Advanced

Cluster

When VERITAS Database Edition/Advanced Cluster for Real Application Clusters

or VERITAS Cluster Server 4.0 (I/O fencing function) is used

6

TPRLO

When all the following conditions are satisfied:

The host mode 0C Windows or 2C Windows Extension is used

The Emulex host bus adapter is used

The mini-port driver is used

TPRLO=2 is specified for the mini-port driver parameter of the host bus adapter

7

Automatic

recognition function

of LUN

When all the following conditions are satisfied:

The host mode 00 Standard or 09 Solaris is used

SUN StorEdge SAN Foundation Software Version 4.2 or later is used

You want to automate recognition of increase and decrease of devices when a

genuine SUN HBA is connected

12

Undisplay function of

ghost LUN

When all the following conditions are satisfied:

The host mode 08 HP is used

You want to suppress creation of device files for devices to which the paths are

not defined

13

SIM report at link

failure

When the user wants to be informed by SIM (service information message) that the

number of link failures detected between ports exceeds the threshold.

14

HP TruCluster with

TrueCopy function

When all the following conditions are satisfied:

The host mode 07 Tru64 is used

You want to use TruCluster to set a cluster to the Continuous Access XP P-VOL

and S-VOL, respectively

Advertising
This manual is related to the following products: