Switching to standard or high-speed mode, Operational restrictions, Restrictions on lun manager operations – HP XP LUN Configuration and Security Manager Software User Manual

Page 34: Table 11 lun manager operation restrictions, 11 lun manager operation restrictions

Advertising
background image

34

LUN Manager for the XP10000/XP12000

6.

Click Apply. A confirmation message appears.

7.

Click OK. The settings are applied to the disk array.

Switching to standard or high-speed mode

Channel adapter boards can be set for standard or high-speed mode. If possible, apply high-speed mode

to channel adapters to improve the system performance. Be aware that you can only apply high-speed or

high-speed (2 port) mode to channel adapters that satisfy certain requirements.

1.

Start LUN Manager, and display the LUN Manager pane (

Figure 7

).

2.

In the Package tree on the Port pane, right-click a channel adapter (CHA) package. A shortcut menu

appears. The current mode is preceded by a bullet.

3.

Select the mode that you want. A confirmation message appears.

4.

Click OK.

5.

Click Apply. A confirmation message appears.

6.

Click OK. The settings are applied to the disk array.

NOTE:

Storage partition administrators cannot apply High Speed mode.

Operational restrictions

The success of some LUN Manager activities depends on the status of the security switch and whether I/O

is active or inactive to the port or LUN. The following tables describe those restrictions.

NOTE:

Do not remove LU paths (see

Changing or viewing LU path settings

” on page 26) when the hosts are

performing I/O processing.

Do not remove LUN security (see

Applying and removing LUN security

” on page 31) when the hosts

are performing I/O processing.

Restrictions on LUN Manager operations

Table 11

LUN Manager operation restrictions

Activity

Security switch OFF

Security switch ON

Host group 0

Host group

01-7F

Host group 0

Host group

01-7F

Setting the LUN

Security Switch

ON

With active I/O

on port

Permitted with

confirmation

message

Invalid operation

Invalid operation

With no active

I/O on port

Setting the LUN

Security Switch

OFF

With active I/O

on port

Invalid operation

Permitted with confirmation

message

With no active

I/O on port

Adding a host

group

With active I/O

on port

Default host

group

Not permitted

Default host

group

Permitted

With no active

I/O on port

Advertising
This manual is related to the following products: