Lun manager for the xp10000/xp12000, Lu configuration overview, Fibre channel environment – HP XP LUN Configuration and Security Manager Software User Manual

Page 11: Supported emulation types, Lu paths, Host storage domains, 1 lun manager for the xp10000/xp12000

Advertising
background image

LUN Configuration and Security Manager XP user guide for the XP10000/XP12000

11

1

LUN Manager for the XP10000/XP12000

You can connect XP arrays to open system and mainframe hosts using Fibre Channel. Use LUN Manager to

configure host groups, logical units (LUs), and Fibre Channel ports.

LU configuration overview

One of the important tasks in logical unit (LU) configuration is to define I/O paths from hosts to LUs. After

the paths are defined, the hosts can send commands and data to the LUs and can receive data from them.
LUN Manager can also configure security policies to protect LUs from unauthorized access.

Fibre Channel environment

In a Fibre Channel environment, you must configure the Fibre Channel ports on the disk array. With LUN

Manager, you can set addresses and speed, and specify topology for Fibre Channel ports.

Supported emulation types

LUN Manager supports the following device emulation types:

OPEN-3, OPEN-9, OPEN-8 (XP128/XP1024 only), OPEN-E, OPEN-L, and OPEN-V for open systems

3390-3A/B/C and 3380-KA/B/C for mainframe systems

LU paths

After hosts and the disk array are physically connected by cables, switches, and so on, use LUN Manager

to establish paths between the hosts and LUs. These paths are called LU paths and they determine which

host can access which LU.

Up to 256 LU paths can be defined for a host group in a Fibre Channel environment

Up to 1,024 LU paths can be defined for a Fibre Channel port for the XP10000/XP12000 array

Up to 256 host groups can be defined for a Fibre Channel port for the XP10000/XP12000 array

Up to 65,536 host groups can be defined for one disk array (256 x 256)

Up to 255 hosts can be included in all the host groups for one Fibre Channel port

Configuring LU paths in a Fibre Channel environment

Before defining LU paths, you must classify server hosts by host storage domains. For example, if Linux and

Windows

®

hosts are connected to the disk array, you must create a separate host storage domain for each

host type. When this is done, register the host bus adapters for each host type in the appropriate host

storage domain.

Host storage domains

A host storage domain can contain only hosts that are connected to the same port and cannot contain

hosts that are connected to different ports. For example, if two Windows hosts are connected to port 1A

and three Windows hosts are connected to port 1B, you cannot register all five Windows hosts in one host

storage domain. You must register the first two Windows hosts in one host storage domain and the

remaining three Windows hosts in another host storage domain.
After server hosts are classified into host storage domains, you must associate host storage domains to

logical volumes. In

Figure 1

, the host storage domain hg-lnx is associated with the logical volumes 00:00,