Loop prevention, Connecting virtual connect ethernet module uplinks – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 45

Advertising
background image

Installation 45

Loop prevention

When link is established on a Virtual Connect Ethernet module port, the port exchanges LLDP packets with
the far-side connection. This LLDP protocol is an IEEE 802.1 standard that makes use of special BPDU

packets that are not forwarded by Ethernet bridges or switches. As part of the LLDP exchange, Virtual

Connect can determine whether a Virtual Connect Ethernet module port is connected to another port

within the same Virtual Connect domain. If the port is connected, the port is designated as a stacking link
and treated as such. If the port is not connected, then the port is available for use as an uplink port.
Only ports that have not been designated as an uplink port in a network are eligible to become stacking

links. If a port has been designated as an uplink port, and then is subsequently connected to another

Virtual Connect Ethernet module, the port will not become a stacking link until it is removed from the
network definition as an uplink port.
To avoid network loops, Virtual Connect must first verify that only one active uplink exists per network

from the Virtual Connect domain to the external Ethernet switching environment. Second, Virtual Connect

must be sure that no network loops are created by the stacking links between Virtual Connect modules.

One active link—A VC uplink set can include multiple uplink ports. To prevent a loop with broadcast

traffic coming in one uplink and going out another, only one uplink or uplink LAG is active at a time.
The uplink or LAG with the greatest bandwidth should be selected as the active uplink. If the active

uplink loses link, then the next best uplink will be made active.

No loops through stacking links—If multiple Virtual Connect Ethernet modules are used, they are
interconnected via stacking links, which might appear as an opportunity for loops within the VC

environment. For each individual network in the Virtual Connect environment, VC will block certain

stacking links to ensure that each network has a loop-free topology.

The loop avoidance feature can not be disabled or changed. However, the preferred uplink connection

for a network can be identified when defining network uplinks.

Connecting Virtual Connect Ethernet module uplinks

Each interconnect module has several numbered Ethernet connectors. All of these connectors can be used

to connect to data center switches (uplink ports) or they can be used to stack Virtual Connect modules as
part of a single Virtual Connect domain (stacking ports). See "Recommended stacking connections (on

page

43

)."

Networks must be defined within the Virtual Connect Manager so that specific, named networks can be

associated with specific external data center connections. See "Define Ethernet Network screen (on page

103

)." These named networks can then be used to specify networking connectivity for individual servers.

See "Ethernet Networks (Server Connections) screen (on page

109

)."

The following sections provide an overview of the types of external connections and their behaviors.
Mapping individual networks to individual external uplink ports
The simplest approach to connecting the defined networks to the data center is to map each network to a

specific external uplink port. This uplink port is defined by the following:

Enclosure name

Interconnect bay containing the Virtual Connect Ethernet module